SHTNAK=0, BFRE=0, TYPE=00, DIR=0, DBLB=0
Pipe Configuration Register
EPNUM | Endpoint Number |
DIR | Transfer Direction 0 (0): Receiving direction 1 (1): Transmitting direction |
SHTNAK | Pipe Disabled at End of Transfer 0 (0): Continue pipe operation after transfer ends 1 (1): Disable pipe after transfer ends |
DBLB | Double Buffer Mode 0 (0): Single buffer 1 (1): Double buffer |
BFRE | BRDY Interrupt Operation Specification 0 (0): Generate BRDY interrupt on transmitting or receiving data 1 (1): Generate BRDY interrupt on completion of reading data |
TYPE | Transfer Type 0 (00): Pipe not used 1 (01): Pipes 1 and 2: Bulk transfer Pipes 3 to 5: Bulk transfer Pipes 6 to 9: Setting prohibited 2 (10): Pipes 1 and 2: Setting prohibited Pipes 3 to 5: Setting prohibited Pipes 6 to 9: Interrupt transfer 3 (11): Pipes 1 and 2: Isochronous transfer Pipes 3 to 5: Setting prohibited Pipes 6 to 9: Setting prohibited |